The BA-SW30, a best-selling focused shockwave therapy device, has already been put into use in major markets. We have compiled an FAQ about the machine for those who are still considering it. If these questions do not fully help you, please feel free to contact us. We will provide you with one-on-one exclusive Q&A service.

When buying a shockwave therapy device, what should I start by considering?
Choose a shockwave therapy device that meets your clinical indications and intended use. Shockwaves are broadly classified into two types: focused shockwaves and ballistic shockwaves.
Focused shockwave therapy is suitable for deep, focal, and refractory lesions, as well as bone lesions, such as calcific tendinitis, deep tendinopathy, nonunion/delayed healing/stress fractures, early osteonecrosis, chronic plantar fasciitis, deep myofascial trigger points, erectile dysfunction, chronic wounds and scars, frozen shoulder, osteoarthritis pain, and chronic bursitis. Radial shockwave therapy is suitable for superficial, diffuse soft tissue problems, such as plantar fasciitis, Achilles tendinitis, Achilles tendinopathy, tennis elbow, golfer’s elbow, patellar tendinitis, rotator cuff tendinopathy, myofascial pain syndrome and trigger points, lateral hip pain, iliotibial band syndrome, carpal tunnel syndrome, superficial nonunion fractures, muscle spasms, and fascial adhesion release.
When purchasing, select the appropriate shockwave therapy device based on the indications and verify that the equipment’s functionality and clinical data support these uses.

Differences between Focused Shockwave Therapy and Radial Shockwave Therapy
The two types of shockwave therapy differ in their energy generation methods, energy propagation methods, focusing methods, depth of action, and clinical positioning.
Focused shockwave therapy concentrates acoustic energy within the body, using electromagnetic/piezoelectric/electrohydraulic methods to focus it at a specific point. It boasts a clear focal point and high energy density, allowing for precise positioning and concentrated coverage. It is commonly used for deep pain, tendons, bones, and erectile dysfunction (ED).

What is EFD?
EFD stands for Energy Flux Density, measured in mJ/mm², and is an energy parameter of focused shock wave therapy equipment. It represents the amount of energy delivered to each square millimeter of tissue within the focal region by each shock wave.
Its clinical range is ~0.08–0.60 mJ/mm².
What is the difference between EFD and BAR? Are they related?
Bar is a unit of pressure, commonly used as a key sales parameter in radial shockwave therapy devices. It directly represents the compressed air pressure driving the projectile, a directly controllable operating parameter of the equipment, and is clearly related to output intensity. However, bar is essentially a driving/operational parameter and cannot be directly equated to the final acoustic output peak pressure or EFD.
EFD is energy flux density, i.e., energy output per unit area, typically used as a sales parameter for focused shockwave therapy. Its final value needs to be determined based on the measured peak pressure, pulse frequency, focal depth data, and the specific measurement method.
Bar and EFD represent different physical parameters. Bar is a pressure indicator, while EFD represents acoustic energy per unit area; they cannot be directly converted.
How to adjust the focusing depth of a focused shockwave therapy device?
Focused shockwave therapy comes in three types: electromagnetic, piezoelectric, and electrohydraulic.
Electromagnetic focused shockwave therapy adjusts the focusing depth by changing or moving the focusing structure, treatment head, or altering the geometric distance. Piezoelectric focused shockwave therapy adjusts the focusing depth by changing the probe with different focal lengths and altering its acoustic structure. Electrohydraulic focused shockwave therapy adjusts the focusing depth by changing the geometry of the reflector/ellipsoid or using reflectors with different focal lengths.
For shockwave therapy, how many pulses are needed per session, what is the frequency, how should the energy be set, and how many treatment sessions are required for a cure? What should the interval between treatments be set?
The treatment parameters, treatment sessions, and intervals should be set according to the clinical indications. Different symptoms require completely different treatment parameters.
What is the focal depth of the BA-SW30?
The maximum focal/treatment depth of the BA-SW30 is 70mm.
How many strikes per minute can BA-SW30 do assuming the power remains constant?
Depending on the frequency setting, the number of hits per minute ranges from 30 to 180.
What type of shockwave technology does the BA-SW30 use?
The BA-SW30 employs focused electromagnetic shockwave technology. It outputs a 3μs shockwave by electromagnetically driving a metal diaphragm to vibrate, converging towards a specific focal area to achieve a treatment depth of 7cm.
How is the BA-SW30 different from a pneumatic/radial shockwave device?
The two shockwave devices differ in their energy generation, propagation, focusing, depth of action, and clinical application.
The BA-SW30 focused shockwave is suitable for deep tissue treatment. It uses electromagnetic, piezoelectric, or electrohydraulic methods to converge energy at a focal point, providing a clear focus and high energy density for precise targeting and concentrated coverage. It is commonly used for deep pain, tendons, bones, and erectile dysfunction (ED).
Pneumatic/radial shockwave, on the other hand, diffuses shock energy radially from the probe into the tissue. The energy is released through a ballistic system within the handle. It lacks a clear focal point, has a medium to low energy density, and can cover a larger treatment area. It is commonly used for superficial muscles, fascia, soft tissues, and pain.
What is the EFD of the BA-SW30?
At a depth of focus of 70mm, the EFD value per pulse is approximately 0.35-0.4 mJ/mm².
What conditions can BA-SW30 be used for?
Established clinical applications of focused extracorporeal shock wave therapy include various musculoskeletal disorders, plantar fasciitis, lateral epicondylitis, Achilles tendinopathy, patellar tendinopathy, rotator cuff tendinitis, nonunion/delayed union of fractures, and erectile dysfunction.
Can the BA-SW30 be used for erectile dysfunction?
Focused shockwave therapy has been clinically studied for the treatment of erectile dysfunction. The indications and marketing effectiveness of the BA-SW30 depend on the regulatory approvals applicable in your market. Currently, customers who have purchased the BA-SW30 are using it for ED treatment in many countries across Europe and America.
How many shots can the BA-SW30‘s applicator/handpiece deliver?
The BA-SW30‘s applicator/handpiece has a minimum of 500,000 shots. The handpiece itself will only exceed this number.
What is the warranty period for the BA-SW30?
The BA-SW30 focused shockwave machine comes with a 3-year warranty. Under non-human-caused damage, we provide comprehensive machine maintenance services.
Which consumables for the BA-SW30 need to be replaced regularly?
The BA-SW30‘s external water system requires replacement of distilled/purified water depending on usage, duration, and video frequency. No other consumables require periodic replacement.
Does the price of the BA-SW30 include operator training?
Yes, it does. Bamboolaser provides a complete operator training system as standard, including:
- Pre-shipment training: Before the equipment is shipped, our engineers will provide online basic operation training to the key personnel of the purchasing party, including handle usage, interface operation, energy adjustment, and daily maintenance;
- Installation training: After the equipment arrives, Bamboolaser will provide one-on-one online guidance for installation, debugging, and operation training to ensure that operators can independently complete standard treatment procedures;
- Training materials: Bamboolaser will include an operation manual, a start-up guide, a safety precautions checklist, and instructional videos with the equipment.
Does purchasing the BA-SW30 include treatment plans and clinical training?
Regarding the BA-SW30 focused shockwave therapy device, we understand that the depth of clinical application directly impacts treatment outcomes. Therefore, we provide probe selection for various indications, energy parameter optimization and individualized adjustment, contraindication identification and adverse reaction management, and the setup of combination therapy regimens. We regularly update case studies and provide support.
Does the BA-SW30 focused shockwave therapy device offer OEM/ODM branding services?
Bamboolaser fully supports OEM/ODM cooperation. We have a complete R&D, production, and registration support system, and can provide OEM branding services, including silkscreen/laser engraving of the device exterior, a full set of branded materials such as packaging boxes and instruction manuals, and customized startup screens.
Deep ODM customization is also available. Upon reaching a minimum order quantity, the exterior structure can be redesigned, including colors, shapes, and handle styles; additions or removals of functional modules and deep customization of software functions can also be completed.
We will also sign a cooperation guarantee to protect your brand and channels, providing an exclusive regional agency protection policy (depending on order volume).